Temperature Analysis of Coronal Loop Cross-Sections: Monolithic vs. Nanoflare Heating

Other

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

We present a first systematic study on the cross-sectional temperature structure of coronal loops using the six coronal temperature filters of the Atmospheric Imaging Assembly (AIA) instrument on the Solar Dynamics Observatory (SDO). We analyze a sample of 100 loop snapshots measured at 10 different locations and 10 different times in active region NOAA 11089 on 2010 July 24, 21:00-22:00 UT.
The cross-sectional flux profiles are measured and a cospatial background is subtracted in 6 filters in a temperature range of T ≈ 0.5-16 MK, and 4 different parameterizations of differential emission measure (DEM) distributions are fitted. We find that the reconstructed DEMs consist predominantly of narrowband peak temperature components with a thermal width of σlog(T) ≤ 0.11±0.02, close to the temperature resolution limit of the instrument, consistent with earlier triple-filter analysis from TRACE by Aschwanden and Nightingale (2005) and from EIS/Hinode by Warren et al. (2008) or Tripathi et al. (2009). We find that 66% of the loops could be fitted with a narrowband single-Gaussian DEM model, and 19% with a DEM consisting of two narrowband Gaussians (which mostly result from pairs of intersecting loops along the same line-of-sight). The mostly isothermal loop DEMs allow us also to derive an improved empirical response function of the AIA 94 [[Unable to Display Character: Ǻ]] filter, which needs to be boosted by a factor of q94 = 6.7± 1.7 for temperatures at log(T)

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Temperature Analysis of Coronal Loop Cross-Sections: Monolithic vs. Nanoflare Heating does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Temperature Analysis of Coronal Loop Cross-Sections: Monolithic vs. Nanoflare Heating, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Temperature Analysis of Coronal Loop Cross-Sections: Monolithic vs. Nanoflare Heating will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-943327

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.