Astronomy and Astrophysics – Astrophysics
Scientific paper
Oct 2000
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2000head....5.4304m&link_type=abstract
American Astronomical Society, HEAD Meeting #5, #43.04; Bulletin of the American Astronomical Society, Vol. 32, p.1259
Astronomy and Astrophysics
Astrophysics
Scientific paper
The Chandra mirrors, the HRMA, have the best angular resolution that any X-ray telescope has yet achieved. This results in images with a resolution of about 0.5 arc-second PSF (FWHM). In spite of this value, the pixel size of the CCD(0.492arc-second) is not small enough for the full imaging capability of Chandra to be realized by using the ACIS. Since the primary charge cloud generated by an X-ray photon has a finite size [1], the charge distribution of the X-ray event will give us more precise position information than that determined by the pixel size. In particular, the location of ASCA-grade 6 events, corner pixel events, can be localized to about one tenth of the pixel size as confirmed by employing the identical ACIS CCD [2] and by the mesh technique [3]. Therefore, we can expect an improvement of the position resolution by collecting corner pixel events. We are applying this technique to all the available data in the public archive, from stars to AGNs. In the meeting, we will report the validity of this technique and discuss the results from the astrophysical point of view. [1] J. Hiraga, H. Tsunemi, K. Yoshita, E. Miyata, and M. Ohtani, ``How big are charge clouds inside the charge-coupled device produced by X-ray photons ?'' Jpn. J. Appl. Phys., Vol. 37, 4627, 1998. [2] M. Pivovaroff, S. Jones, M. Bautz, S. Kissel, G. Prigozhin, G. Ricker, H. Tsunemi, and E. Miyata, ``Measurement of the Sub-pixel Structure of AXAF CCDs,'' IEEE Trans. Nucl. Sci., Vol. 45, 164, 1998. [3] H. Tsunemi, S. Kitamoto, and K. Yoshita, ``New Technique of the X-Ray Efficiency Measurement of a Charge-Coupled Device with a Subpixel Resolution.'' Jpn. J. Appl. Phys., Vol. 36, 2906, 1998.
Baluta Christopher J.
Miyata Emi
Mori Koji
Tsunemi Hiroshi
Tsunemi Laboratory Team
No associations
LandOfFree
High quality images obtained with the Chandra ACIS through introducing of subpixel resolution of the CCD does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with High quality images obtained with the Chandra ACIS through introducing of subpixel resolution of the CCD, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and High quality images obtained with the Chandra ACIS through introducing of subpixel resolution of the CCD will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-873526