Computer Science
Scientific paper
Apr 2002
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=2002cqgra..19.1697n&link_type=abstract
Classical and Quantum Gravity, Volume 19, Issue 7, pp. 1697-1702 (2002).
Computer Science
12
Scientific paper
We systematically measured the intrinsic mechanical quality factors of 13 kinds of bulk fused silica from four companies using a nodal support system. Some of them have actually been adopted as mirror substrates in interferometric gravitational wave detectors. The measured quality factors widely ranged from 7 × 105 to 4 × 107. They turned out to be independent of one specific property, such as the amount of OH content, suggesting that the loss mechanism has several origins. We found that many of the samples showed smaller losses at lower frequency. From the viewpoint of the mirror thermal noise, it would be fortunate if the loss continued to decrease with decreasing frequency. We also found that an annealing process increases their quality factors.
Ando Masaki
Numata Kenji
Otsuka Shigemi
Tsubono Kimio
No associations
LandOfFree
Intrinsic losses in various kinds of fused silica does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Intrinsic losses in various kinds of fused silica, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Intrinsic losses in various kinds of fused silica will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-840699