An Investigation of Mars NIR Spectral Features using Absolutely Calibrated Images

Other

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

We used the NSFCAM 256x256 InSb array camera at the NASA Infrared Telescope Facility to gather near-infrared (NIR) spectral image sets of Mars through the 1995 opposition. In previous studies with these data [1-6] we noted several interesting spectral features, some of which are diagnostic volatile absorption bands that allow the discrimination between CO_2 or H_2O ices. Band depth maps of these regions show polar and morning and evening limb ices composed of water and some indication of polar CO_2 ices. Other features, near 3.33 and 3.4\micron, appear to be confined to particular geographic regions; specifically Syrtis Major. However, the images used in these previous studies were calibrated to either the disk average or only to a rough scaled reflectance by simple division by solar-type star data gathered at the same time as the images. This only allowed determinations of spectral features either relative to some global average of the feature, or to some unit not directly comparable to other published data. For at least three of our observation nights the conditions and data are sufficient to absolutely calibrate the images to radiance factors. For this work we reinvestigate the spectra and band depth mapping results using these absolutely calibrated images. In general we find that bright regions have peak radiance factors of 0.5 to 0.6 at 2.25\micron\ and 0.3 to 0.4 at 3.5\micron; dark regions have radiance factors of 0.2 to 0.25 at 2.25\micron\ and 0.1 to 0.15 at 3.5\micron. Overall, precision errors are about 0.025 in radiance factor and absolute errors are at the 10-15% level. These results are consistent with previous studies that found radiance factors of 0.35 in Tharsis, 0.47 in Elysium, and 0.26 in dark regions at 2.25\micron\ [7,8] and 0.3 in bright regions and 0.1 in dark regions at 3.5\micron\ [8]. These absolute flux values will allow direct comparison of these results to radiative transfer models of the behavior of the surface and atmosphere and also provide an independent measurement for comparison to, and calibration of, imaging and spectral data acquired by spacecraft orbiting Mars. References [1] Bell III J. F., et al. (1995) BAAS, 27, 1091. [2] Klassen D. R. et al.(1995) BAAS, 27, 1061. [3] Bell III J. F. et al. (1996a) J. Geophys. Res., 101, 9227. [4] Bell III J. F. et al. (1996b) BAAS, 28, 1063. [5] Klassen D. R. (1997) Ph.D. Dissertation, Univ. Wyoming. [6] Klassen D. R. et al. (1998) LPSC XXIX, abstract no. 1658. [7] Bell III J. F. et al. (1994) Icarus, 111, 106. [8] Roush T. L. et al. (1992) Icarus, 99, 42.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

An Investigation of Mars NIR Spectral Features using Absolutely Calibrated Images does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with An Investigation of Mars NIR Spectral Features using Absolutely Calibrated Images, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and An Investigation of Mars NIR Spectral Features using Absolutely Calibrated Images will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-813866

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.