Long-term monitoring of the W44C (G 34.3+0.15) maser in the 1.35 cm water vapor and 18 cm hydroxyl lines

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Results of monitoring the H2O and OH masers in W44C, located near the cometary HII region G34.3+0.15, are reported. Observations in the water-vapor line at λ = 1.35 cm were carried out on the 22-meter radio telescope of the Pushchino Radio Astronomy Observatory (Russia) from November 1979 to March 2011, and in the hydroxyl lines at λ = 18 cm on the large Nançay radio telescope (France). Activity maxima and minima of the water maser alternated. The average period of the activity is ˜ 14 years, consistent with results obtained earlier for a number of other sources associated with regions of active star formation. In periods of enhanced maser activity, two series of strong H2O maser flares were observed, which were related to two different clusters of maser spots located at the front of a shock at the periphery of the ultracompact region UH II. These series of flares may be associated with cyclic activity of the protostellar object in UH II. In the remaining time intervals, there were mainly short-lived flares of single features. The Stokes parameters for the observations in the hydroxyl lines were determined. Zeeman splitting was observed in the profile of the 1667 MHz OH main line at a velocity of 58.5 km/s, and was used to estimate the intensity of the line-of-sight component of the magnetic field (1.2 mG).

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Long-term monitoring of the W44C (G 34.3+0.15) maser in the 1.35 cm water vapor and 18 cm hydroxyl lines does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Long-term monitoring of the W44C (G 34.3+0.15) maser in the 1.35 cm water vapor and 18 cm hydroxyl lines, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Long-term monitoring of the W44C (G 34.3+0.15) maser in the 1.35 cm water vapor and 18 cm hydroxyl lines will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-751739

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.