The Effect of 53 micron IR Radiation on 18 cm OH Megamaser Emission

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Accepted to ApJ, 26 pages including 1 table and 7 figures

Scientific paper

10.1086/533429

OH megamasers (OHMs) emit primarily in the main lines at 1667 and 1665 MHz, and differ from their Galactic counterparts due to their immense luminosities, large linewidths and 1667/1665 MHz flux ratios, which are always greater than one. We find that these maser properties result from strong 53 micron radiative pumping combined with line overlap effects caused by turbulent linewidths of about 20 km/s; pumping calculations that do not include line overlap are unreliable. A minimum dust temperature of about 45 K is needed for inversion, and maximum maser efficiency occurs for dust temperatures in the range 80 - 140 K. We find that warmer dust can support inversion at lower IR luminosities, in agreement with observations. Our results are in good agreement with a clumpy model of OHMs, with clouds sizes about 1 pc and OH column densities about 5e16 cm^2, that is able to explain both the diffuse and compact emission observed for OHMs. We suggest that all OH main line masers may be pumped by far-IR radiation, with the major differences between OHMs and Galactic OH masers caused by differences in linewidth produced by line overlap. Small Galactic maser linewidths tend to produce stronger 1665 MHz emission. The large OHM linewidths lead to inverted ground state transitions having approximately the same excitation temperature, producing 1667/1665 MHz flux ratios greater than one and weak satellite line emission. Finally, the small observed ratio of pumping radiation to dense molecular gas, as traced by HCN and HCO$^+$, is a possible reason for the lack of OH megamaser emission in NGC 6240.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

The Effect of 53 micron IR Radiation on 18 cm OH Megamaser Emission does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with The Effect of 53 micron IR Radiation on 18 cm OH Megamaser Emission, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The Effect of 53 micron IR Radiation on 18 cm OH Megamaser Emission will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-691449

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.