All-Stokes Parameterization of the Main Beam and First Sidelobe for the Arecibo Radio Telescope

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

42 pages, 18 figures, accepted by PASP

Scientific paper

10.1086/323290

We describe a scheme that characterizes the main beam and sidelobe in all Stokes parameters employing parameters that allow reconstruction of the complete beam patterns and, also, afford an easy way to see how the beam changes with azimuth, zenith angle, and time. For the main beam in Stokes I the parameters include the beam width, ellipticity and its orientation, coma and its orientation, the point-source gain, the integrated gain (or, equivalently, the main beam efficiency); for the other Stokes parameters the beam parameters include beam squint and beam squash. For the first sidelobe ring in Stokes I the parameters include an 8-term Fourier series describing the height, radius, and radial width; for the other Stokes parameters they include only the sidelobe's fractional polarization. We illustrate the technique by applying it to the Arecibo telescope. The main beam width is smaller and the sidelobe levels higher than for a uniformly-illuminated aperture of the same effective area. These effects are modeled modestly well by a blocked aperture, with the blocked area equal to about 10% of the effective area (this corresponds to 5% physical blockage). In polarized emission, the effects of beam squint (difference in pointing direction between orthogonal polarizations) and squash (difference in beamwidth between orthogonal polarizations) do not correspond to theoretical expectation and are higher than expected; these effects are almost certainly caused by the blockage. The first sidelobe is highly polarized because of blockage.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

All-Stokes Parameterization of the Main Beam and First Sidelobe for the Arecibo Radio Telescope does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with All-Stokes Parameterization of the Main Beam and First Sidelobe for the Arecibo Radio Telescope, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and All-Stokes Parameterization of the Main Beam and First Sidelobe for the Arecibo Radio Telescope will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-581163

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.