New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

8 pages, 8 figures

Scientific paper

10.1103/PhysRevC.79.045807

Liquid xenon is an important detection medium in direct dark matter experiments, which search for low-energy nuclear recoils produced by the elastic scattering of WIMPs with quarks. The two existing measurements of the relative scintillation efficiency of nuclear recoils below 20 keV lead to inconsistent extrapolations at lower energies. This results in a different energy scale and thus sensitivity reach of liquid xenon dark matter detectors. We report a new measurement of the relative scintillation efficiency below 10 keV performed with a liquid xenon scintillation detector, optimized for maximum light collection. Greater than 95% of the interior surface of this detector was instrumented with photomultiplier tubes, giving a scintillation yield of 19.6 photoelectrons/keV electron equivalent for 122 keV gamma rays. We find that the relative scintillation efficiency for nuclear recoils of 5 keV is 0.14, staying constant around this value up to 10 keV. For higher energy recoils we measure a value around 20%, consistent with previously reported data. In light of this new measurement, the XENON10 experiment's results on spin-independent WIMP-nucleon cross section, which were calculated assuming a constant 0.19 relative scintillation efficiency, change from $8.8\times10^{-44}$ cm$^2$ to $9.9\times10^{-44}$ cm$^2$ for WIMPs of mass 100 GeV/c$^2$, and from $4.4\times10^{-44}$ cm$^2$ to $5.6\times10^{-44}$ cm$^2$ for WIMPs of mass 30 GeV/c$^2$.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and New Measurement of the Relative Scintillation Efficiency of Xenon Nuclear Recoils Below 10 keV will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-491497

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.