Improving PSF calibration in confocal microscopic imaging---estimating and exploiting bilateral symmetry

Statistics – Applications

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Published in at http://dx.doi.org/10.1214/10-AOAS343 the Annals of Applied Statistics (http://www.imstat.org/aoas/) by the Ins

Scientific paper

10.1214/10-AOAS343

A method for estimating the axis of reflectional symmetry of an image $f(x,y)$ on the unit disc $D=\{(x,y):x^2+y^2\leq1\}$ is proposed, given that noisy data of $f(x,y)$ are observed on a discrete grid of edge width $\Delta$. Our estimation procedure is based on minimizing over $\beta\in[0,\pi)$ the $L_2$ distance between empirical versions of $f$ and $\tau_{\beta}f$, the image of $f$ after reflection at the axis along $(\cos\beta,\sin\beta)$. Here, $f$ and $\tau_{\beta}f$ are estimated using truncated radial series of the Zernike type. The inherent symmetry properties of the Zernike functions result in a particularly simple estimation procedure for $\beta$. It is shown that the estimate $\hat{\beta}$ converges at the parametric rate $\Delta^{-1}$ for images $f$ of bounded variation. Further, we establish asymptotic normality of $\hat{\beta}$ if $f$ is Lipschitz continuous. The method is applied to calibrating the point spread function (PSF) for the deconvolution of images from confocal microscopy. For various reasons the PSF characterizing the problem may not be rotationally invariant but rather only reflection symmetric with respect to two orthogonal axes. For an image of a bead acquired by a confocal laser scanning microscope (Leica TCS), these axes are estimated and corresponding confidence intervals are constructed. They turn out to be close to the coordinate axes of the imaging device. As cause for deviation from rotational invariance, this indicates some slight misalignment of the optical system or anisotropy of the immersion medium rather than some irregular shape of the bead. In an extensive simulation study, we show that using a symmetrized version of the observed PSF significantly improves the subsequent reconstruction process of the target image.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Improving PSF calibration in confocal microscopic imaging---estimating and exploiting bilateral symmetry does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Improving PSF calibration in confocal microscopic imaging---estimating and exploiting bilateral symmetry, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Improving PSF calibration in confocal microscopic imaging---estimating and exploiting bilateral symmetry will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-427510

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.