The He II Fowler lines and the O III and N III Bowen fluorescence lines in the symbiotic nova RR Tel

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Accepted version for Astronomy and Astrophysics

Scientific paper

A new measure of reddening (E$_{(B-V)}$$\sim$0.00) has been obtained from the comparison between the observed and the theoretical intensity decrement for 20 emission lines of the $\ion{He}{ii}$ Fowler (n$\to$3) series. This value has been confirmed by the STIS and IUE continuum distribution, and by the value of n$_H$ from the damped profile of the IS H Ly-$\alpha$ line. We have obtained very accurate measurements for about thirty Bowen lines of $\ion{O}{iii}$ and a precise determination of the efficiency in the O1 and O3 excitation channels (18 % and 0.7 %, respectively). The relative $\ion{O}{iii}$ intensities are in good agreement with the predictions by Froese Fischer (1994). A detailed study of the decays from all levels involved in the Bowen mechanism has lead to the detection of two new $\ion{O}{iii}$ Bowen lines near $\lambda$ 2190. High resolution IUE data have shown a nearly linear decline with time, from 1978 to 1995, in the efficiency of the O1 and O3 processes, with a steeper slope for the O3 channel. A detailed study of the $\ion{N}{iii}$ $\lambda$ 4640 lines and of their excitation mechanism has shown that, recombination and continuum fluorescence being ruled out, line fluorescence remains the only viable mechanism to pump the 3d $^2D_{5/2}$ and 3d $^2D_{3/2}$ levels of $\ion{N}{iii}$. We point out the important role of multiple scattering in the resonance lines of $\ion{O}{iii}$ and $\ion{N}{iii}$ near $\lambda$ 374 and show that the observed $\ion{N}{iii}$ line ratios and intensities can be explained in terms of line fluorescence by the three resonance lines of $\ion{O}{iii}$ at $\lambda$$\lambda$ 374.432, 374.162 and 374.073 under optically thick conditions.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

The He II Fowler lines and the O III and N III Bowen fluorescence lines in the symbiotic nova RR Tel does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with The He II Fowler lines and the O III and N III Bowen fluorescence lines in the symbiotic nova RR Tel, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The He II Fowler lines and the O III and N III Bowen fluorescence lines in the symbiotic nova RR Tel will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-422270

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.