Far and mid infrared observations of two ultracompact H II regions and one compact CO clump

Astronomy and Astrophysics – Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

To appear in Astronomy & Astrophysics; (19 pages including 14 Figures and 6 Tables)

Scientific paper

10.1051/0004-6361:20021662

Two ultracompact H II regions (IRAS 19181+1349 and 20178+4046) and one compact molecular clump (20286+4105) have been observed at far infrared wavelengths using the TIFR 1 m balloon-borne telescope and at mid infrared wavelengths using ISO. Far infrared observations have been made simultaneously in two bands with effective wavelengths of ~ 150 and ~ 210 micron, using liquid 3He cooled bolometer arrays. ISO observations have been made in seven spectral bands using the ISOCAM instrument; four of these bands cover the emission from Polycyclic Aromatic Hydrocarbon (PAH) molecules. In addition, IRAS survey data for these sources in the four IRAS bands have been processed using the HIRES routine. In the high resolution mid infrared maps as well as far infrared maps multiple embedded energy sources have been resolved. There are structural similarities between the images in the mid infrared and the large scale maps in the far infrared bands, despite very different angular resolutions of the two. Dust temperature and optical depth (tau_150 um) maps have also been generated using the data from balloon-borne observations. Spectral energy distributions (SEDs) for these sources have been constructed by combining the data from all these observations. Radiation transfer calculations have been made to understand these SEDs. Parameters for the dust envelopes in these sources have been derived by fitting the observed SEDs. In particular, it has been found that radial density distribution for three sources is diffrent. Whereas in the case of IRAS 20178+4046, a steep distribution of the form r^-2 is favoured, for IRAS 20286+4105 it is r^-1 and for IRAS 19181+1349 it the uniform distribution (r^0). Line ratios for PAH bands have generally been found to be similar to those for other compact H II regions but different from general H II regions.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Far and mid infrared observations of two ultracompact H II regions and one compact CO clump does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Far and mid infrared observations of two ultracompact H II regions and one compact CO clump, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Far and mid infrared observations of two ultracompact H II regions and one compact CO clump will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-240926

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.