The Lick AGN Monitoring Project: Velocity-Delay Maps from the Maximum-Entropy Method for Arp 151

Astronomy and Astrophysics – Astrophysics – Cosmology and Extragalactic Astrophysics

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

7 pages, 5 figures, accepted for publication in the Astrophysical Journal Letters

Scientific paper

We present velocity-delay maps for optical H I, He I, and He II recombination lines in Arp 151, recovered by fitting a reverberation model to spectrophotometric monitoring data using the maximum-entropy method. H I response is detected over the range 0-15 days, with the response confined within the virial envelope. The Balmer-line maps have similar morphologies but exhibit radial stratification, with progressively longer delays for Hgamma to Hbeta to Halpha. The He I and He II response is confined within 1-2 days. There is a deficit of prompt response in the Balmer-line cores but strong prompt response in the red wings. Comparison with simple models identifies two classes that reproduce these features: freefalling gas, and a half-illuminated disk with a hotspot at small radius on the receding lune. Symmetrically illuminated models with gas orbiting in an inclined disk or an isotropic distribution of randomly inclined circular orbits can reproduce the virial structure but not the observed asymmetry. Radial outflows are also largely ruled out by the observed asymmetry. A warped-disk geometry provides a physically plausible mechanism for the asymmetric illumination and hotspot features. Simple estimates show that a disk in the broad-line region of Arp 151 could be unstable to warping induced by radiation pressure. Our results demonstrate the potential power of detailed modeling combined with monitoring campaigns at higher cadence to characterize the gas kinematics and physical processes that give rise to the broad emission lines in active galactic nuclei.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

The Lick AGN Monitoring Project: Velocity-Delay Maps from the Maximum-Entropy Method for Arp 151 does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with The Lick AGN Monitoring Project: Velocity-Delay Maps from the Maximum-Entropy Method for Arp 151, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and The Lick AGN Monitoring Project: Velocity-Delay Maps from the Maximum-Entropy Method for Arp 151 will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-215687

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.