Scaling of temperature- and pressure-dependent viscosity convection

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Abstract In a series of three-dimensional spherical simulations the effects of purely internally heated convection was studied to yield updated scaling laws for parameterized mantle convection models similar to 2D boxed approaches as [1], [2]. The upper Rayleigh number, the viscosity contrast due to temperature and pressure were varied in over 88 cases to study the influence of these parameters on the quasi steady-state. A viscosity contrast up to the order of 109 was observed. The simulations were carried out using the new GAIA framework, consisting of a highly parallel solver for mantle convection in arbitrary geometries. Updated values for the Nusselt - Rayleigh scaling are presented together with a new mobility criterion to specify the stagnant lid regime. Furthermore, the parametric ranges of degree-one convection are presented along with a new spectral scaling that allows the determination of the internal Rayleigh number from dominant spherical harmonic modes of convective systems. If the viscosity contrast within the system reaches a certain limit, the style changes to stagnant lid convection. In the regime of stagnant lid convection, the dominant mode increases if the internal Rayleigh number is increased as well, while in the non-stagnant lid regime the modes stay low (bifurcation), as shown in figure 1. Comparing the results to those previously published ([1], [2], [3], [4]) in the same parameter range in 2D and 3D boxes exposed an interesting increase of the γ parameter relating the transition to the stagnant lid regime. It seems that 2D or 3D boxed runs produce a stagnant lid while in a sphere fall into degree-one convection without a stagnant lid. A transitional or sluggish regime could not be observed. The viscosity contrast at which stagnant lid convection occurs could be pin-pointed to 2.96e4 with a confidence interval of less than +/-2.7e3. Spectral analysis revealed also that stagnant lid convection cannot happen below a degreefour pattern and that degree-one convection is not possible for iso-viscous convection because the range in which degree-one convection would occur leads to a Rayleigh number not high enough to enable convection. The newly derived spectral scaling law was applied to gravity field observations of Venus to constrain and compare internal parameters such as viscosity and temperature at the convecting interior with previously published values. References [1] Solomatov, V.S. and Moresi, L.-N. (2000) JGR, 105, p.21,795-21,817. [2] Grasset, O. and Parmentier, E.M. (1998) JGR, 103, p18,171-18,181 [3] Dumoulin, C., Doin, M.-P. and Fleitout, L. (1999) JGR, 104, p.12,759-12,777. [4] Reese, C.C., Solomatov, V.S., Baumgardner, J.R., Yang, W.-S. (1999) PEPI, 116, p1-7.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Scaling of temperature- and pressure-dependent viscosity convection does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Scaling of temperature- and pressure-dependent viscosity convection, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Scaling of temperature- and pressure-dependent viscosity convection will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1794114

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.