Statistics – Applications
Scientific paper
Jan 1998
adsabs.harvard.edu/cgi-bin/nph-data_query?bibcode=1998aipc..420.1595t&link_type=abstract
Space technology and applications international forum - 1998. AIP Conference Proceedings, Volume 420, pp. 1595-1606 (1998).
Statistics
Applications
Scientific paper
A model was developed to calculate the vapor pressure losses and characterize the vapor flow regimes on the cathode side of multitube vapor-anode AMTEC cells, with internal chevrons radiation shields and TiN electrodes. Results showed that the vapor flow on the cathode side of the AMTEC cells was typically in the transition regime, and that the pressure losses due to the chevrons shield constituted about 50% of the total pressure loss. Such an increase in the vapor pressure losses, however, decreased the cell electrical power output by only about 5%, because the concentration losses in the cell were small compared to the charge-exchange polarization and internal ohmic losses.
El-Genk Mohamed S.
Tournier Jean-Michel
No associations
LandOfFree
Sodium vapor flow regimes and pressure losses on cathode side of multitube AMTEC cell does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.
If you have personal experience with Sodium vapor flow regimes and pressure losses on cathode side of multitube AMTEC cell, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Sodium vapor flow regimes and pressure losses on cathode side of multitube AMTEC cell will most certainly appreciate the feedback.
Profile ID: LFWR-SCP-O-1652582