Effects of secondary electron emission on charge pulses from a z-stack microchannel plate photon-counting detector with a crossed delay line anode readout

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

A study of the effects of secondary electron emission on charge pulses from a microchannel plate (MCPs) photon counting detector with crossed delay line (CDL) anode readout is presented. The detector is a 2D photon counting detector with fast count rate and good spatial resolution being developed at Los Alamos National Laboratory. The CDL anode is constructed of two orthogonal planar pairs of helically wound wires on inner and outer ceramic sides attached to a copper ground plane. The electron cloud event from the MCPs interacts with the wires generating a signal pulse. The electronics that strike the wire with sufficient energy generate secondary electrons. A model is presented for the charge pulses from the CDL anode incorporating the effects of secondary electron emission. An empirical test of the model is conducted with two different wire materials using a demountable MCP/CDL detector. Charge pulses are measured and the results are compared to the model. The result show that the charge pulses from the CDL anode are material dependent and exhibit the general behavior predicted by the model. Secondary electron emission is an integral part of the CDL anode charge pulses and must be considered in further developments of the CDL anode readout.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Effects of secondary electron emission on charge pulses from a z-stack microchannel plate photon-counting detector with a crossed delay line anode readout does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Effects of secondary electron emission on charge pulses from a z-stack microchannel plate photon-counting detector with a crossed delay line anode readout, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Effects of secondary electron emission on charge pulses from a z-stack microchannel plate photon-counting detector with a crossed delay line anode readout will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1545350

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.