Uncooled nonequilibrium HgCdTe IR detector modeling

Computer Science

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The narrow gap semiconductor HgCdTe is commonly used for IR detection. Conventional HgCdTe IR detectors need significant cooling in order to reduce noise and leakage currents resulting from thermal generation and recombination processes. These cooling requirements considerably increase the cost, size, weight and complexity of infrared systems. The need for cooling to reduce noise and leakage currents resulting from Auger processes has long been thought to be fundamental and inevitable. However, recently, it has been suggested that by means of a steady-state non-equilibrium mode of operation, which holds the carrier densities below their equilibrium values, Auger generation and even radiative generation rates can be reduced. This is possible through the reduction of carrier concentrations because the Auger generation rate depends approximately on the square of the carrier concentration and radiative recombination rate depends linearly on it. This paper reports the modeling of a HgCdTe detector operated in a steady-state non-equilibrium mode at 230 approximately equals 295 K. The device architecture, NvP+, which is practical in MBE growth, is suitable for this application. Radiative and Auger lifetimes, zero surface recombination velocities, and zero background photon fluxes are assumed. The dependence of detectivity on minority carrier extraction efficiency is studied in this paper. At 230 and 250 K for ND equals 1 X 1014approximately equals 15 cm-3, the detectivity appears to become saturated at values in the order of 1010 cm Hz1/2/W when the minority carrier extraction efficiency is greater than 3.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Uncooled nonequilibrium HgCdTe IR detector modeling does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Uncooled nonequilibrium HgCdTe IR detector modeling, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Uncooled nonequilibrium HgCdTe IR detector modeling will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1483990

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.