Operations of the Far Ultraviolet Spectroscopic Explorer : A `Dynamic' Flux Calibration.

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

The FUSE flux calibration is based on model-atmosphere predictions of the spectra of well studied white-dwarf stars. Calibration operations, however, are a highly `dynamic' process consisting of repeatedly measuring these standard stars, deriving corrections, and integrating the results into CALFUSE, the FUSE science pipeline. With suitable scheduling, those calibration observation campaigns let us characterize short term and long term variations of the sensitivity. One particular issue addressed by these observations is monitoring possible degradation of the FUSE optical coatings by atomic oxygen present in the upper atmosphere. We have attempted to minimize this by avoiding pointing close to the instantaneous velocity vector of the spacecraft (the ram vector). Prior to Cycle 3, the minimum permitted angle between the line of sight and the ram vector was 20 degrees. This was reduced to 15 degrees during Cycle 3 to increase our sky coverage, and will be further reduced to 10 degrees for Cycle 4. This relaxation of ram constraints has been preceded by a tailored calibration program in which white dwarf measurements are obtained before and after observations performed for a limited time below the current ram vector constraint. This relaxation of the ram vector constraint will considerably expand the ability of FUSE to observe sources at low declination.
This work is based on data obtained for the Guaranteed Time Team by the NASA-CNES-CSA FUSE mission operated by the Johns Hopkins University. Financial support to U.S. participants has been provided by NASA contract NAS5-32985.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Operations of the Far Ultraviolet Spectroscopic Explorer : A `Dynamic' Flux Calibration. does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Operations of the Far Ultraviolet Spectroscopic Explorer : A `Dynamic' Flux Calibration., we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Operations of the Far Ultraviolet Spectroscopic Explorer : A `Dynamic' Flux Calibration. will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1366755

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.