Frequency of Oxygen VI in Intervening QSO Absorption Systems

Mathematics – Logic

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

We have conducted the first survey for QSO with O VI lambda lambda 1032,1038 absorption lines. We obtained medium resolution (R ~ 1300), high signal-to-noise (~ 20) spectra of 11 QSOs (0.53<= zem <=2.08) taken with the Faint Object Spectrograph from the Hubble Space Telescope Archive. The O VI doublet is found exclusively in the Lyman-alpha forest. All previous surveys of metal lines in QSO absorption systems were done redward of Lyalpha emission, avoiding blending due to Lyman-alpha forest clouds. The higher density of lines in the Lyman-alpha forest demands new stringent criteria to ensure the identification of the O VI doublet. We used simulated spectra to determine the statistical significance of lines indentified in the Lyman-alpha forest. We found 12 O VI doublets and 9 are expected to be real. Six constitute a uniform sample with both lines exceeding a rest equivalent width of W_r =0.21 Angstroms. The number of O VI doublets per unit redshift is = 1.0 +/-0.6 at a mean absorption redshift of zave = 0.9. For comparable W_r the density of O VI absorbers is similar to Mg II (Tytler et al 1986; Steidel & Sargent 1992) and C IV absorbers (Sargent et al 1988; Bahcall et al 1993). We searched for other common ions in the O VI absorption systems. Out of 8 O VI absorption systems in which C IV is also found, C IV is stronger in all except zabs=1.0828 towards PG1206+459 which we believe is collisionally ionized. A rough estimate of the cosmological mass density of O VI is carried out. If we assume that O VI lines are linear, we get a lower limit of Omega (OVI) >= 3 times 10(-9) h(-1}_{100) . Since O > O VI, if the mean metal abundance were below 0.002 solar, then the accompanying Hydrogen and Helium would account for all baryons in the universe. We conclude that mean abundances are above 0.002 solar, and much greater if the gas is not highly ionized (O >> O VI).

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Frequency of Oxygen VI in Intervening QSO Absorption Systems does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Frequency of Oxygen VI in Intervening QSO Absorption Systems, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Frequency of Oxygen VI in Intervening QSO Absorption Systems will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1321515

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.