Why Do Soft X-Rays Weaken With Increasing QSO Luminosity?

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

As far back as 1980, it was known that optically-selected QSOs show a decrease in their X-ray emission relative to optical as a function of luminosity. Is this trend the result of a softening of the intrinsic spectral energy distribution (SED) as a function of luminosity, or an effect extrinsic to the energy production mechanism? Intrinsic absorption lines in UV spectra of QSOs range from narrow line associated absorbers to deep, broad absorption lines, spanning up to 2 orders of magnitude in equivalent width. Recent results from the ROSAT All Sky Survey, and from deep ROSAT pointings reveal that broad absorption line quasars (BALQSOs) are weak in the soft X-ray bandpass (alpha_ {ox}>1.8) in comparison to QSOs with normal optical/UV spectra (/line{alpha_ {ox}}=1.4). Less spectacular UV absorbers show significant soft X-ray absorption as well. Could X-ray faintness in QSOs largely be caused by the same absorbers producing the apparent UV absorption? Is it possible that the alpha_ {ox}(Lopt) correlation is itself caused by absorption? This hypothesis can already be at least weakly tested by 1) excluding known BALs from a large optical/X-ray sample and 2) removing QSOs with any known absorption. Our results are consistent with, but put no strong constraints on the hypothesis that the weakening of soft X-rays with luminosity are due to absorption. We note that if at least some of the correlation is caused by increased warm absorption at higher luminosities, then it should weaken in soft X-ray selected samples.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Why Do Soft X-Rays Weaken With Increasing QSO Luminosity? does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Why Do Soft X-Rays Weaken With Increasing QSO Luminosity?, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Why Do Soft X-Rays Weaken With Increasing QSO Luminosity? will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1177181

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.