Major-Element Ratios of 433 Eros: New Calibration of the NEAR-Shoemaker X-ray Spectrometer Data

Astronomy and Astrophysics – Astronomy

Scientific paper

Rate now

  [ 0.00 ] – not rated yet Voters 0   Comments 0

Details

Scientific paper

Elemental abundance ratios for six elements (Mg, Al, Si, S, Ca, Fe) in the surface layer of 433 Eros were derived [1,2] from solar-induced fluorescence measured by the NEAR-Shoemaker X-ray spectrometer (XRS). Calibration of these data depended critically on knowledge of the incident solar spectrum.
Unfortunately, the gas solar monitor carried by NEAR was inadequately calibrated prior to launch. Previously published XRS results were based partly on broadband measurements by the Earth-orbiting GOES-8 (Geostationary Operational Environmental Satellites) X-ray detectors and partly on a preliminary solar monitor calibration carried out by the present authors. The new solar monitor calibration is based on a more recent set of physical models of the solar spectrum at various temperatures [3,4], an improved fitting procedure, analysis of a large number of flight spectra, and comparison with concurrent data from the GOES and YOHKOH BCS X-ray detectors. The elemental composition of the surface of 433 Eros will be discussed together with the new estimates of systematic uncertainties.
[1] Trombka, J.I., et al. (2000) Science 289, 2101-2105. [2] Nittler, L.R., et al. (2001) Meteorit. Planet. Sci. 36, 1673-1695. [3] Dere, K.P., et al. (1997) A&AS 125, 149-173. [4] Young, P.R., et al. (2003) ApJS 144, 135-152.

No associations

LandOfFree

Say what you really think

Search LandOfFree.com for scientists and scientific papers. Rate them and share your experience with other people.

Rating

Major-Element Ratios of 433 Eros: New Calibration of the NEAR-Shoemaker X-ray Spectrometer Data does not yet have a rating. At this time, there are no reviews or comments for this scientific paper.

If you have personal experience with Major-Element Ratios of 433 Eros: New Calibration of the NEAR-Shoemaker X-ray Spectrometer Data, we encourage you to share that experience with our LandOfFree.com community. Your opinion is very important and Major-Element Ratios of 433 Eros: New Calibration of the NEAR-Shoemaker X-ray Spectrometer Data will most certainly appreciate the feedback.

Rate now

     

Profile ID: LFWR-SCP-O-1013986

  Search
All data on this website is collected from public sources. Our data reflects the most accurate information available at the time of publication.